<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>EBAA - Moria - Alchimia</title>
	<atom:link href="https://alchimiasrl.com/information/meeting-presentations/ebaa/feed/" rel="self" type="application/rss+xml" />
	<link>https://alchimiasrl.com/information/meeting-presentations/ebaa/</link>
	<description>Your ideas, our solutions</description>
	<lastBuildDate>Fri, 06 Mar 2020 09:08:58 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://alchimiasrl.com/wp-content/uploads/2020/03/cropped-Icon-per-sito-32x32.jpg</url>
	<title>EBAA - Moria - Alchimia</title>
	<link>https://alchimiasrl.com/information/meeting-presentations/ebaa/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Development of a new corneal storage medium with antimycotic tablet Cornea Forum 2017</title>
		<link>https://alchimiasrl.com/development-of-a-new-corneal-storage-medium-with-antimycotic-tablet-cornea-forum-2017/</link>
		
		<dc:creator><![CDATA[Michela Stocco]]></dc:creator>
		<pubDate>Tue, 14 Nov 2017 11:37:36 +0000</pubDate>
				<category><![CDATA[Cornea and Eye Banking Forum]]></category>
		<category><![CDATA[EBAA]]></category>
		<category><![CDATA[Eye Banking]]></category>
		<category><![CDATA[Human Tissue Processing products]]></category>
		<category><![CDATA[KERASAVE]]></category>
		<category><![CDATA[Meeting presentations]]></category>
		<category><![CDATA[R&D]]></category>
		<category><![CDATA[R&D Presentations]]></category>
		<guid isPermaLink="false">https://alchimiasrl.com/?p=13108</guid>

					<description><![CDATA[<p>Year: 2017, Cornea and Eye Banking Forum Authors: D'Amato Tóthová J. Co-Authors: Pateri F.; Giurgola L.; Limongelli A.; Tomasiello D.; Frigerio E.; Mistò R. Online presentation   Purpose: Cold corneal storage media available on the market do not contain antimycotics. A new corneal storage medium with an antimycotic tablet (Kerasave, AL.CHI.MI.A. S.r.l.) was developed to prevent fungal  [...]</p>
<p>L'articolo <a href="https://alchimiasrl.com/development-of-a-new-corneal-storage-medium-with-antimycotic-tablet-cornea-forum-2017/">Development of a new corneal storage medium with antimycotic tablet Cornea Forum 2017</a> proviene da <a href="https://alchimiasrl.com">Moria - Alchimia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="fusion-fullwidth fullwidth-box fusion-builder-row-1 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-first" style="--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% ) * 0.33333333333333 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-1 hover-type-none"><img decoding="async" width="200" height="200" title="EBAA 200 SITO" src="https://alchimiasrl.com/wp-content/uploads/2018/11/EBAA-200-SITO.png" alt class="img-responsive wp-image-12300" srcset="https://alchimiasrl.com/wp-content/uploads/2018/11/EBAA-200-SITO-66x66.png 66w, https://alchimiasrl.com/wp-content/uploads/2018/11/EBAA-200-SITO-100x100.png 100w, https://alchimiasrl.com/wp-content/uploads/2018/11/EBAA-200-SITO-150x150.png 150w, https://alchimiasrl.com/wp-content/uploads/2018/11/EBAA-200-SITO.png 200w" sizes="(max-width: 200px) 100vw, 200px" /></span></div></div><div class="fusion-text fusion-text-1"><p><strong>Year:</strong> 2017, Cornea and Eye Banking Forum</p>
<p><strong>Authors</strong>: D&#8217;Amato Tóthová J.</p>
<p><strong>Co-Authors</strong>: Pateri F.; Giurgola L.; Limongelli A.; Tomasiello D.; Frigerio E.; Mistò R.</p>
<p><a href="http://videoed.corneasociety.org/content/cornea-and-eye-banking-forum">Online presentation</a></p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_2_3 2_3 fusion-two-third fusion-column-last" style="--awb-bg-size:cover;width:66.666666666667%;width:calc(66.666666666667% - ( ( 4% ) * 0.66666666666667 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-2"><p><span class="fontstyle2"><strong>Purpose:</strong> </span><span class="fontstyle0">Cold corneal storage media available on the market do not contain antimycotics. A new corneal storage medium with an antimycotic tablet (Kerasave, AL.CHI.MI.A. S.r.l.) was developed to prevent fungal contamination of donor corneas intended for transplantation. The aim of this study was to assess the antimycotic activity of the new cold storage medium, Kerasave, and to evaluate the quality of donor corneas preserved in the medium at 4°C for 14 days in comparison with Optisol GS.<br />
</span></p>
<p><span class="fontstyle2"><strong>Method(s): </strong></span><span class="fontstyle0">Kerasave antimycotic activity was determined by </span><span class="fontstyle0">in vitro </span><span class="fontstyle0">time-kill studies using sterile porcine corneal tissues, contaminated with 10 cfu/ml of </span><em><span class="fontstyle0">C. Albicans </span></em><span class="fontstyle0">(ATCC10231 and clinical isolate). The killing rate of the microorganisms was monitored at 4°C after 5 and 10 days of incubation in Kerasave.<br />
Kerasave performance was assessed on 16 pairs of human corneas not suitable for transplantation, procured and evaluated according to standard procedures of Monza Eye Bank, Italy. One cornea was transferred in Kerasave and the contralateral in Optisol GS. Endothelial cell density (ECD), measured by specular microscopy (Keratoanalyzer, Konan), was evaluated pre-processing, and after 7 and 14 days of storage at 4°C. Endothelial cell morphology and mortality were determined according to Stocker method, and epithelial integrity, and corneal transparency were evaluated using a Slit lamp.<br />
</span><span class="fontstyle0"><br />
</span><span class="fontstyle2"><strong>Results: </strong></span><span class="fontstyle0">In vitro </span><span class="fontstyle0">time-kill studies showed 3.6 log reduction for both Candida strains after 5 days of incubation at 4°C and 4 log reduction was observed for both strains after 10 days of incubation.</span><br />
Kerasave -and Optisol-GS- treated tissues showed similar ECD, mortality and endothelial morphology after 7 and 14 days of cold storage. Slit lamp analysis showed comparable corneal transparency and epithelial integrity in both groups.</p>
<p><span class="fontstyle2"><strong>Conclusion: </strong></span><span class="fontstyle0">The new cold storage medium with antimycotic tablet, Kerasave, exhibited an excellent antimycotic activity and biocompatibility with donor corneas after corneal storage at 4°C for up to 14 days.</span></p>
</div><div class="fusion-clearfix"></div></div></div></div></div>
<p>L'articolo <a href="https://alchimiasrl.com/development-of-a-new-corneal-storage-medium-with-antimycotic-tablet-cornea-forum-2017/">Development of a new corneal storage medium with antimycotic tablet Cornea Forum 2017</a> proviene da <a href="https://alchimiasrl.com">Moria - Alchimia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Suitability for Transplantation of Corneas From Donors 76 to 80 Years Old</title>
		<link>https://alchimiasrl.com/suitability-for-transplantation-of-corneas-from-donors-76-to-80-years-old/</link>
		
		<dc:creator><![CDATA[Michela Stocco]]></dc:creator>
		<pubDate>Sat, 28 Nov 2009 16:49:53 +0000</pubDate>
				<category><![CDATA[EBAA]]></category>
		<category><![CDATA[Eusol-C]]></category>
		<category><![CDATA[Eye Banking]]></category>
		<category><![CDATA[Human Tissue Processing products]]></category>
		<category><![CDATA[Meeting presentations]]></category>
		<guid isPermaLink="false">https://alchimiasrl.com/?p=12775</guid>

					<description><![CDATA[<p>Year: 2009, EBAA Authors: Gangadhar D.; Abdullayev E.; Kalankhodjaev B.; Abdullayev A.   Abstract: Older donor cornea (76-80 yrs old) were stored in Eusol-C and transplanted. None of the recipients developed postoperative endophthalmitis or other inflammatory complications at 3 month post-op and visual acuity was improved in 98% of patients.</p>
<p>L'articolo <a href="https://alchimiasrl.com/suitability-for-transplantation-of-corneas-from-donors-76-to-80-years-old/">Suitability for Transplantation of Corneas From Donors 76 to 80 Years Old</a> proviene da <a href="https://alchimiasrl.com">Moria - Alchimia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="fusion-fullwidth fullwidth-box fusion-builder-row-2 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-first" style="--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% ) * 0.33333333333333 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-2 hover-type-none"><img decoding="async" width="200" height="200" title="EBAA 200 SITO" src="https://alchimiasrl.com/wp-content/uploads/2018/11/EBAA-200-SITO.png" alt class="img-responsive wp-image-12300" srcset="https://alchimiasrl.com/wp-content/uploads/2018/11/EBAA-200-SITO-66x66.png 66w, https://alchimiasrl.com/wp-content/uploads/2018/11/EBAA-200-SITO-100x100.png 100w, https://alchimiasrl.com/wp-content/uploads/2018/11/EBAA-200-SITO-150x150.png 150w, https://alchimiasrl.com/wp-content/uploads/2018/11/EBAA-200-SITO.png 200w" sizes="(max-width: 200px) 100vw, 200px" /></span></div></div><div class="fusion-text fusion-text-3"><p><strong>Year: </strong>2009, EBAA</p>
<p><strong>Authors</strong>: Gangadhar D.; Abdullayev E.; Kalankhodjaev B.; Abdullayev A.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_2_3 2_3 fusion-two-third fusion-column-last" style="--awb-bg-size:cover;width:66.666666666667%;width:calc(66.666666666667% - ( ( 4% ) * 0.66666666666667 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-4"><p><strong>Abstract: </strong>Older donor cornea (76-80 yrs old) were stored in Eusol-C and transplanted. None of the recipients developed postoperative endophthalmitis or other inflammatory complications at 3 month post-op and visual acuity was improved in 98% of patients.</p>
</div><div class="fusion-clearfix"></div></div></div></div></div>
<p>L'articolo <a href="https://alchimiasrl.com/suitability-for-transplantation-of-corneas-from-donors-76-to-80-years-old/">Suitability for Transplantation of Corneas From Donors 76 to 80 Years Old</a> proviene da <a href="https://alchimiasrl.com">Moria - Alchimia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>New corneal preservation media. Eusol-C vs. Optisol-GS</title>
		<link>https://alchimiasrl.com/new-corneal-preservation-media-eusol-c-vs-optisol-gs/</link>
		
		<dc:creator><![CDATA[Michela Stocco]]></dc:creator>
		<pubDate>Tue, 28 Nov 2006 16:46:23 +0000</pubDate>
				<category><![CDATA[EBAA]]></category>
		<category><![CDATA[Eusol-C]]></category>
		<category><![CDATA[Eye Banking]]></category>
		<category><![CDATA[Human Tissue Processing products]]></category>
		<category><![CDATA[Meeting presentations]]></category>
		<guid isPermaLink="false">https://alchimiasrl.com/?p=12773</guid>

					<description><![CDATA[<p>Year: 2006, EBAA Authors: Chaibpracob J.; Phillips R.; Hardenbergh F.   Abstract: Eusol-C is a widely used European media for cold corneal storage. In the present study we compared Eusol-C to Optisol-GS. Following transplantation,  corneal endothelial cell densities and corneal thickness were similar between Optisol-preserved corneas and Eusol-preserved corneas.</p>
<p>L'articolo <a href="https://alchimiasrl.com/new-corneal-preservation-media-eusol-c-vs-optisol-gs/">New corneal preservation media. Eusol-C vs. Optisol-GS</a> proviene da <a href="https://alchimiasrl.com">Moria - Alchimia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="fusion-fullwidth fullwidth-box fusion-builder-row-3 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-4 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-first" style="--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% ) * 0.33333333333333 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-3 hover-type-none"><img decoding="async" width="200" height="200" title="EBAA 200 SITO" src="https://alchimiasrl.com/wp-content/uploads/2018/11/EBAA-200-SITO.png" alt class="img-responsive wp-image-12300" srcset="https://alchimiasrl.com/wp-content/uploads/2018/11/EBAA-200-SITO-66x66.png 66w, https://alchimiasrl.com/wp-content/uploads/2018/11/EBAA-200-SITO-100x100.png 100w, https://alchimiasrl.com/wp-content/uploads/2018/11/EBAA-200-SITO-150x150.png 150w, https://alchimiasrl.com/wp-content/uploads/2018/11/EBAA-200-SITO.png 200w" sizes="(max-width: 200px) 100vw, 200px" /></span></div></div><div class="fusion-text fusion-text-5"><p><strong>Year:</strong> 2006, EBAA</p>
<p><strong>Authors: </strong>Chaibpracob J.; Phillips R.; Hardenbergh F.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-5 fusion_builder_column_2_3 2_3 fusion-two-third fusion-column-last" style="--awb-bg-size:cover;width:66.666666666667%;width:calc(66.666666666667% - ( ( 4% ) * 0.66666666666667 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-6"><p><strong>Abstract: </strong>Eusol-C is a widely used European media for cold corneal storage. In the present study we compared Eusol-C to Optisol-GS. Following transplantation,  corneal endothelial cell densities and corneal thickness were similar between Optisol-preserved corneas and Eusol-preserved corneas.</p>
</div><div class="fusion-clearfix"></div></div></div></div></div>
<p>L'articolo <a href="https://alchimiasrl.com/new-corneal-preservation-media-eusol-c-vs-optisol-gs/">New corneal preservation media. Eusol-C vs. Optisol-GS</a> proviene da <a href="https://alchimiasrl.com">Moria - Alchimia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Eusol-C effectiveness as a corneal storage media EEBA 2006</title>
		<link>https://alchimiasrl.com/eusol-c-effectiveness-as-a-corneal-storage-media-eeba-2006/</link>
		
		<dc:creator><![CDATA[Michela Stocco]]></dc:creator>
		<pubDate>Tue, 28 Nov 2006 16:44:15 +0000</pubDate>
				<category><![CDATA[EBAA]]></category>
		<category><![CDATA[Eusol-C]]></category>
		<category><![CDATA[Eye Banking]]></category>
		<category><![CDATA[Human Tissue Processing products]]></category>
		<category><![CDATA[Meeting presentations]]></category>
		<guid isPermaLink="false">https://alchimiasrl.com/?p=12769</guid>

					<description><![CDATA[<p>Year: 2006, EEBA Authors: Scott Bryan G.; Abdullayev E.; Wellemeyer M.; Gangadhar D. JR.; Sandlin C.   Abstract: Eusol-C is an effective alternative corneal storage media to the more widely used Optisol-GS. Eusol-C maintained donor cornea viability, similarly to Optisol-GS. New Backlight Corneal Microscopy had significant advantages over traditional slit lamp microscopy for donor corneas evaluation  [...]</p>
<p>L'articolo <a href="https://alchimiasrl.com/eusol-c-effectiveness-as-a-corneal-storage-media-eeba-2006/">Eusol-C effectiveness as a corneal storage media EEBA 2006</a> proviene da <a href="https://alchimiasrl.com">Moria - Alchimia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="fusion-fullwidth fullwidth-box fusion-builder-row-4 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-6 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-first" style="--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% ) * 0.33333333333333 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-4 hover-type-none"><img decoding="async" src="https://alchimiasrl.com/wp-content/uploads/2018/11/eeba-logo-1.png" alt class="img-responsive wp-image-12305"/></span></div></div><div class="fusion-text fusion-text-7"><p><strong>Year:</strong> 2006, EEBA</p>
<p><strong>Authors:</strong> Scott Bryan G.; Abdullayev E.; Wellemeyer M.; Gangadhar D. JR.; Sandlin C.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-7 fusion_builder_column_2_3 2_3 fusion-two-third fusion-column-last" style="--awb-bg-size:cover;width:66.666666666667%;width:calc(66.666666666667% - ( ( 4% ) * 0.66666666666667 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-8"><p><strong>Abstract: </strong>Eusol-C is an effective alternative corneal storage media to the more widely used Optisol-GS. Eusol-C maintained donor cornea viability, similarly to Optisol-GS. New Backlight Corneal Microscopy had significant advantages over traditional slit lamp microscopy for donor corneas evaluation prior to transplant.</p>
</div><div class="fusion-clearfix"></div></div></div></div></div>
<p>L'articolo <a href="https://alchimiasrl.com/eusol-c-effectiveness-as-a-corneal-storage-media-eeba-2006/">Eusol-C effectiveness as a corneal storage media EEBA 2006</a> proviene da <a href="https://alchimiasrl.com">Moria - Alchimia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Eusol-C effectiveness as a corneal storage media</title>
		<link>https://alchimiasrl.com/eusol-c-effectiveness-as-a-corneal-storage-media/</link>
		
		<dc:creator><![CDATA[Michela Stocco]]></dc:creator>
		<pubDate>Mon, 28 Nov 2005 16:43:04 +0000</pubDate>
				<category><![CDATA[EBAA]]></category>
		<category><![CDATA[Eusol-C]]></category>
		<category><![CDATA[Eye Banking]]></category>
		<category><![CDATA[Human Tissue Processing products]]></category>
		<category><![CDATA[Meeting presentations]]></category>
		<guid isPermaLink="false">https://alchimiasrl.com/?p=12767</guid>

					<description><![CDATA[<p>Year: 2005, EBAA Authors: Scott Bryan G.; Abdullayev E.; Wellemeyer M.; Gangadhar D. JR.; Sandlin C.   Abstract: Eusol-C proved to be an effective alternative corneal storage media,  maintaining donor corneal viability comparable with the more widely used Optisol-GS.</p>
<p>L'articolo <a href="https://alchimiasrl.com/eusol-c-effectiveness-as-a-corneal-storage-media/">Eusol-C effectiveness as a corneal storage media</a> proviene da <a href="https://alchimiasrl.com">Moria - Alchimia</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="fusion-fullwidth fullwidth-box fusion-builder-row-5 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-8 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-first" style="--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% ) * 0.33333333333333 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-5 hover-type-none"><img decoding="async" width="200" height="200" title="EBAA 200 SITO" src="https://alchimiasrl.com/wp-content/uploads/2018/11/EBAA-200-SITO.png" alt class="img-responsive wp-image-12300" srcset="https://alchimiasrl.com/wp-content/uploads/2018/11/EBAA-200-SITO-66x66.png 66w, https://alchimiasrl.com/wp-content/uploads/2018/11/EBAA-200-SITO-100x100.png 100w, https://alchimiasrl.com/wp-content/uploads/2018/11/EBAA-200-SITO-150x150.png 150w, https://alchimiasrl.com/wp-content/uploads/2018/11/EBAA-200-SITO.png 200w" sizes="(max-width: 200px) 100vw, 200px" /></span></div></div><div class="fusion-text fusion-text-9"><p><strong>Year:</strong> 2005, EBAA</p>
<p><strong>Authors:</strong> Scott Bryan G.; Abdullayev E.; Wellemeyer M.; Gangadhar D. JR.; Sandlin C.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-9 fusion_builder_column_2_3 2_3 fusion-two-third fusion-column-last" style="--awb-bg-size:cover;width:66.666666666667%;width:calc(66.666666666667% - ( ( 4% ) * 0.66666666666667 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-10"><p><strong>Abstract: </strong>Eusol-C proved to be an effective alternative corneal storage media,  maintaining donor corneal viability comparable with the more widely used Optisol-GS.</p>
</div><div class="fusion-clearfix"></div></div></div></div></div>
<p>L'articolo <a href="https://alchimiasrl.com/eusol-c-effectiveness-as-a-corneal-storage-media/">Eusol-C effectiveness as a corneal storage media</a> proviene da <a href="https://alchimiasrl.com">Moria - Alchimia</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
